Solis S6-EH1P16K03-NV-YD-L Hybrid and Single-Phase Inverter
- 10 seconds of 200% overload capability
- Multiple inverters can operate together to form a microgrid
- Generator-compatible to extend backup duration during grid power outage.
- Supports dual backup ports for intelligent control of critical and non-critical loads.
| MODEL | S6-EH1P16K03-NV-YD-L |
|---|---|
| Recommended max. PV array size | 32kW |
| Max. usable PV input power | 22.4 kW. |
| Max. input voltage | 550 V |
| Start-up voltage | 100 V |
| Rated voltage | 380 V |
| MPP VOLTAGE RANGE | 80 – 520 V. |
| NO. OF MPP TRACKERS | 3 / 6 |
| MAX INPUT CURRENT | 40 A / 40 A / 40 A. |
| MAX. SHORT-CIRCUIT CURRENT | 50 A / 50 A / 50 A. |
| BATTERY TYPE | Li-ion / Lead-acid |
| BATTERY VOLTAGE RANGE | 40 – 60 V. |
| MAX. CHARGE / DISCHARGE CURRENT | 190 A |
| COMMUNICATION | CAN / RS485 |
| RATED OUTPUT POWER | 16 kW |
| RATED GRID VOLTAGE | L/N/PE 220 V / 230 V. |
| RATED GRID FREQUENCY | 50 Hz / 60 Hz |
| RATED GRID OUTPUT CURRENT | 72.7 A / 69.6 A |
| POWER FACTOR | > 0.99 (0.8 leading – 0.8 lagging). |
| THDI | <3% |
| INPUT VOLTAGE RANGE | 187 – 253 V |
| MAX. INPUT CURRENT | 109.1 A / 104.3 A. |
| FREQUENCY RANGE | 45 – 55 Hz / 55 – 65 Hz. |
| RATED OUTPUT POWER | 16kW |
| MAX. APPARENT OUTPUT POWER | 2 times of rated power, 10 s. |
| BACK-UP SWITCH TIME | < 4 ms |
| RATED OUTPUT VOLTAGE | L/N/PE, 220 V / 230 V |
| RATED FREQUENCY | 50 Hz / 60 Hz |
| RATED OUTPUT CURRENT | 72.7 A / 69.6 A. |
| THDV (@LINEAR LOAD) | < 3% |
| MAX.EFFICIENCY | 97.6% |
| EUROPEAN EFFICIENCY | 97.2% |
Battery |
|
| Bat charged by PV max. efficiency | > 94.9% |
| BAT DISCHARGED TO AC MAX. EFFICIENCY | > 94.33% / 93.51%. |
| DC REVERSE POLARITY PROTECTION | yes. |
| GROUND FAULT MONITORING | yes. |
| INTEGRATED AFCI 2.0 | Optional. |
| PROTECTION CLASS / OVER VOLTAGE CATEGORY | I / II (PV and BAT) III (MAINS and BACKUP and GEN). |
| DIMENSIONS (W × H × D) | 464 × 763 × 282 mm |
| WEIGHT | 48.5 kg |
| TOPOLOGY | Transformerless |
| SELF-CONSUMPTION (NIGHT) | < 1 W |
| OPERATING AMBIENT TEMPERATURE RANGE | -25 ~ +60°C. |
| INGRESS PROTECTION | IP66 |
| NOISE EMISSION (TYPICAL) | < 65 dB(A) |
| COOLING CONCEPT | Intelligent fan-cooling. |
| MAX. OPERATION ALTITUDE | 4000 m |
| SAFETY / EMC STANDARD | IEC/EN 62109-1/-2, EN 61000-6-2/-3.. |
| DC CONNECTION | MC4 plug (PV port) / Terminal Block (BAT port). |
| AC CONNECTION | Terminal Block |
| DISPLAY | 7.0″ LCD display & Bluetooth + APP.. |
| COMMUNICATION | RS485, CAN, Optional: Wi-Fi, GPRS, LAN. |
Grid connection standard
NRS 097-2-1/ IEC 62116 / IEC 61727 / IEC 60068, IEC 61683. EN 50530 / MEA / PEA / NBR16149 / NBR 16150.















Solar Panel
Solar Power System
Reviews